Recommended Flux/Wire Combinations of ATLANTIC
for SAW
ATLANTIC Flux/Wire
Combination
AWS Norm
A 5.17
A 5.23
Main Applications
CHF101/CHW-S3
F7A2/EH14
For 500Mpa grade
carbon steel or low alloy steel structures, press vessels, ships, boilers,
etc.
CHF102/CHW-S3
F7A4/EH14
For 500Mpa grade
carbon steel or low alloy steel
CHF101GX/CHW-SG
F7A4/EG-G
Spiral or
longitudinal welded huge diameter pipe made by X65 & X70 steels, or 550Mpa
grade steels, it could be four wires welding and the welding speed is
1,700mm-2,000mm per minute.
CHF101GX/CHW-S9
F7A2/EA2-A2
Spiral or
longitudinal welded huge diameter pipe made by X65 or X70 steel, it could
be four wires welding and the welding speed is 1,700mm-2,000mm per minute.
CHF103/CHW-S2
F6A4/EM12
LPG cylinders, press
vessels, ships, general steel structures, etc.
CHF104/CHW-S2
F7A4/EM12
For 500Mpa grade
carbon steel or low alloy steel structures, press vessels, ships, boilers,
etc.
CHF105/CHW-S3
F7P6/EH14
Low temperature
higher than -50℃ press vessels
CHF113/CHW-S7
F62P4/EA3-A3
For 620Mpa high
tensile low alloy steel structures
CHF115/CHW-S7
F69P2/EA3-A3
For 690Mpa high
tensile low alloy steel structures
CHF301/CHW-S2
F7A0/EM12
For 450Mpa & 500Mpa
grade carbon steel or low alloy steel structures, boilers, etc.
CHF43/CHW-S1
F6A0/EL12
For 450Mpa general
mild steel structures, etc.
CHF101/CHW-S2
F6A4/EM12
LPG cylinders, 450Mpa
grade steel structures, etc.
CHF303/CHW-S4
F7A0/EM13K
For 500Mpa & 550Mpa
grade carbon steel or low alloy steel structures.
CHF603/CHW-S8
F62P2/EB3-B3
For 2.25Cr-1Mo heat
resistant low alloy steel structures, such as T22 P22 (USA), 10CrMo910
(Germany), STBA24, STPA24 (Japan) steels.
CHF301/CHW-S12
F7A0/EM12K
For 500Mpa grade
carbon steel or low alloy steel structures.
CHF101/CHW-S12
F6A4/EM12K
For 450Mpa grade
carbon steel or low alloy steel structures.
AWS A5.17 suitable
for mild steel and AWS A5.23 suitable for low alloy steel
The Definition of SAW
Flux in AWS A5.17 Norm:
F ---- flux
7 ---- The minimum
tensile strength is 70lb/mm
6 ---- The minimum
tensile strength is 60lb/mm
A ---- The weldment
should not be postweld heat treatment
P ---- The weldment
should be postweld heat treatment (620℃ x 1h)
The letter and
figures behind A or P means temperature required of impact V-notch (AKV
27joules)
Letter or Figure
Temperature (℃)
of Test Required
Z
-- (not be
required)
0
-18
2
-29
4
-40
5
-46
6
-51
8
-62
10
-73
15
-101
For Example:
F7A2: A flux combines
a wire to get a deposited metal. Minimum tensile strength of this
deposited metal is 70lb/mm, the weldment should not be postweld heat
treatment, and –29℃ should be required to get the minimum 27 joules of impact V-notch for the